This item is one new Bird AT-500 2 to 520 MHz Antenna Tester. This is new Bird factory stock with a full factory warranty. Shipping anywhere . International shipping will be quoted upon request. Bird AT Series - AT-500
Antenna Testers
Frequency Characteristics:
Frequency Range AT-500 2 to 520 MHz
Requency Resolution 20 kHz
Frequency Accuracy ± 50 kHz
Number of points 100
Measurements:
Rho 0.000 to 1.000
Match Efficiency 0 to 100%
Return Loss -32 to 0 dB
VSWR 1.00 to 100.00
Measurement Accuracy Rho ± 0.04
Match Efficiency Calculated from Return Loss Rho accuracy
VSWR
Test Port:
Connector N(F) supplied. N, TNC, UHF, BNC, male or female available
VSWR 1.25 max
Directivity 32 dB typical
Measurement Speed: Single Frequency Point 5 readings per second typical
Frequency Sweep 1 sweep per second typical
Field Strength: Range 0 to 100%, relative
Sensitivity Fullscale deflection and 0.22 V/m @ 400 MHz using supplied antenna
PC Interface: RS-232 protocol via DB-9 port
Power Requirements:
Power Supply Rechargeable NiCAD battery system. Unit may be re-charged while operating using a wall adapter (included)
AC Adapter Input 120/240 Vac Output 12Vdc, < 400 mA
General Requirements:
Dimensions 8” x 4-5/8” x 1-3/4” (204 x 118 x 42 mm)
Weight 2.0 lbs (0.9 kg)
Temperature, Operating 0 to 50 °C (32 to 122 °F) Temperature, Storage -40 to +71 °C (-40 to +160 °F)
Humidity 95% ± 5% max (noncondensing)
Compliance Unit complies with MIL-T-28800 Class 5 except for temperature and humidity. Unit is CE-compliant and RoHS compliant.
The Bird AT-Series Antenna Testers provide a cost-effective, fast, graphical way of determining the quality of mobile and base station antennas.
• Rugged, easy-to-use, hand-held design with extended battery life makes it ideal for use in the field.
• Tests the system in VSWR, Return Loss, Match Efficiency, or Reflection Coefficient (Rho)
• Single frequency readings and frequency sweeps allow for everything from pinpointests to system optimization and tuning.
• Can save up to 12 traces for comparison and tracking over time
• RS232 Interface allows communication with a PC for saving traces using the optional software.
Satisfaction Guaranteed!! |